Drive Competitive Edge Line Competitor Semi Electric Bed with Side Rails
Drive Competitive Edge Line Competitor Semi Electric Bed with Side Rails

Drive Competitive Edge Line Competitor Semi Electric Bed with Side Rails

Brand/Manufacturer: DRIVE MEDICAL
Save
Authorized Retailer Badge

Drive Competitive Edge Line Competitor Semi Electric Bed with Side Rails is the most compact bed which makes receiving a hospital bed easier for those patients who need one at home. It comes complete with the bed rails, motor, head board and foot board for the unit. The hospital bed ships with non slip feet making it safer for those patients who are constantly tossing and turning in bed and will ensure the bed moves as minimal as possible.



Looking for Better Prices?

Call us Toll-free at 866 316 0162 for Exclusive Price Offers!

Item #DescPkgPrice 
15560 Bed with Full Side Rails Each $829.99 $579.99
15560-HR Bed with Half Rails Each $889.99 $629.99
15560-PKG Bed with Full Side Rails and Mattress Each $935.99 $659.99
15560-HR-PKG Bed with Half Rails and Mattress Each $935.99 $659.99

Features



  • Drive Competitive Edge Line Competitor Semi Electric Bed with Side Rails comes complete with full side rails and frame mounted retractable receiver bracket to eliminate cross braces and ensure proper placement to reduce loss
  • Adjustable-height bed, deck height is adjustable without tools
  • Large glow in the dark hand pendant has easy-to-use controls for adjusting head and foot deck sections to comfortable positions; built in battery backup and power indicator light
  • In the event of a power failure, a 9 volt battery (not included) located in the hand pendant can lower the head and foot sections to a horizontal position. No crank needed
  • Hand Crank adjustable bed height is easy to raise and lower for comfort and accessibility
  • Ultra light head and foot frame weigh only 42 lbs. each
  • Channel frame construction provides excellent strength and reduced weight
  • Frame safety lock slides over hanger pins to prevent disengaging from bed ends
  • Self-contained motor for reduced weight and noise (same as Delta Ultra Light 1000)
  • UL approved Motor can be installed and removed with patient in bed
  • Molded Plastic Bed end panels are durable, lightweight and attractive to blend with decor
  • Headboard is taller than footboard to better fit home decor, head and foot boards are interchangeable
  • Casters are standard
  • Bed ships in two cartons for ease of handling, delivery and setup
  • Weight Capacity 450 lbs evenly distributed
  • Includes weight of occupant, all accessories such as mattress, side/assist rails, trapeze, any personal affects, etc
  • Click Here For User Manual

More Information

  • Maintenance and Safety Checks
    Electronics

    - Check all controls to make sure all functions work properly
    • Foot control
    • Head control
    - Check all cables for damaged or frayed wires
    • Power cord
    • Pendant cord
    - Check to make sure all plugs are fully inserted or attached
    - Check 9V battery on motor and hand control and replace annually
    Bed Frame and Sleeping Surface
    - Visually check all welds
    • Head section
    • Foot section
    • Main Frame
    - Check joints between sleeping surface sections for loose fasteners
    Cleaning
    - The metal parts of the bed are covered with a powder coating. The bed can be power washed. Clean all coated parts with mild detergent and warm water. Periodically raise head and feet sections of the bed and remove dust from frame. Also, periodically remove mattress and clean mattress dec
    NOTE:
    - The competitor bed can be used with a free standing trapeze or a Drive Medical frame mounted trapeze (Item # 15560TRAPEZE). A trapeze cannot be mounted on the Competitor head board
  • General Warnings
    - DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owners manuals, service manuals or instruction sheets supplied with this product or optional equipment
    - If you are unable to understand the warnings, cautions or instructions, contact a healthcare professional, dealer or technical personnel before attempting to use this equipment - otherwise, injury or damage may occur
    - After the bed has been assembled, always test to make sure that all sections of the bed are properly and securely in place before using
    - ALWAYS use caster locks except when moving the bed
    - Body weight should be evenly distributed over the surface of the bed
    - DO NOT lay, sit or lean in such a way that your entire body weight is placed only on raised head or foot sections of the bed. This includes when assisting the user in repositioning or transferring in or out of bed
    - DO NOT let any individual underneath the bed or in between the raised bed frame components at anytime
    - DO NOT permit more than one person on/in the bed at any time.DO NOT use outdoors
    - DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owners manuals, service manuals or instruction sheets supplied with this product or optional equipment. If you are unable to understand the warnings, cautions or instructions, contact a healthcare professional, dealer or technical personnel before attempting to use this equipment - otherwise, injury or damage may occur
    - Keep all moving parts, including the main frame, mattress deck (head and foot springs/sections) and all drive shafts free of obstruction (i.e. blankets/sheets, heating blankets/pads, tubing, wiring, etc. and other types of products using electric cords which may get tangled around the bed, side rails or legs) during operation of the bed. Keep the product a minimum of 12 inches away from any direct heat source
    - NEVER allow patients to use trapeze or traction units as a total individual weight support
    - DO NOT use attachments not recommended by the manufacturer
    - Once patient assessment concludes that the patients condition increases the chance of entrapment, the bed MUST be in the flat position when left unattended.To reduce the risk of entrapment make certain that the bed rail cross braces
    - DO NOT exceed the width of the mattress
    - Mattress MUST fit bed frame and side rails snugly to reduce the risk of entrapment
  • Bed Rail Warnings
    - Although bed rails are not rated to any specific weight limitation, the bed rails may become deformed or broken if excessive side pressure is exerted on the bed rails. The bed rail is not an assist rail for getting into or out of bed
    - DO NOT use the bed rails as push handles when moving the bed
    - DO NOT install the optional bed rails without reading and understanding all of the instructions in the instruction sheet that accompanies the bed rail kit
  • Electrical Warnings
    - A safety feature of this product includes protection against overheating caused by excessive or extended periods of operation. Depending on the duration, this includes multiple or repeated adjustments or the use of multiple functions at one time
    - To ensure trouble free operation, always allow a slight pause between multiple adjustments and avoid pressing more than one function button at a time. If thermal protection activation should occur, the bed will not respond to pendant commands
    - Given this situation, release the pendant button and allow the bed unit to sit for several minutes. This will allow the protection function time to reset and restore bed function
  • Depending on severity of the initial overheating, this could take up to 30 minutes
  • DO NOT open assemblies such as the motors, pendant, junction boxes or gear boxes
  • No user serviceable parts are inside
  • Only qualified technicians are permitted to repair these parts. If unqualified individuals perform any work on these beds, the warranty is void

Specification

Particulars

Dimensions

Bed Height Minimum Without Casters

11" to 20"

Bed Height Maximum With Casters

14" to 23"

Unit Dimensions

35"W x 84"L

Weight

143 lb

User Weight Limit

450 lb

Warranty

  • 5 years warranty on motor and hand control
  • Lifetime limited warranty on welds and frame
  • 1 year warranty on all other parts and components

Customer Reviews

Questions & Answers


 
 
Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*

 
SubmitCancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopwheelchair.com

Close